GSO OIML R111:2003 Scope

1.1 This standard contains the principal physical characteristics and metrological requirements for weights which are used - for the verification of weighing instruments; - for the verification of weights of a lower class of accuracy; - with weighing instruments. The nominal values of mass of the weights covered by this standard range from 1 milligram (mg) to 50 kilograms (kg). 1.2 This standard applies to weights in classes of accuracy as follows: E1, E2, F1, F2, M1, M2, M3. 1.2.1 Weights used for the verification of weighing instruments The classes of accuracy of the weights used for the verification of weighing instruments shall be specified in the appropriate International Recommendations relating to these instruments. 1.2.2 Weights used for the verification of weights of a lower class of accuracy E1 - Weights intended to ensure traceability (see GSO 1651/2002 paragraph A.3) between national mass standards (with values derived from the International Prototype of the kilogram) and weights of class E2 and lower. Class E1 weights or sets of weights shall always be accompanied by a calibration certificate (see 12.2). E2 - Weights intended to be used for the initial verification of weights of class F1. Class E2 weights or sets of weights shall always be accompanied by a calibration certificate; they may be used as class E1 weights if they comply with the requirements for surface roughness and magnetic susceptibility of class E1 weights and if their calibration certificate gives the appropriate data (specified in 12.2). F1 - Weights intended to be used for the initial verification of weights of class F2. F2 - Weights intended to be used for the initial verification of weights of class M1 and possible M2. _________________________ (1) E: Exceptional, F: Fine, M: Medium. M1 - Weights intended to be used for the initial verification of weights of class M2. M2 - Weights intended to be used for the initial verification of weights of class M3. 1.2.3 Minimum accuracy class of weights used with weighing instruments The accuracy classes of weights used with weighing instruments shall be chosen in accordance with the requirements of GSO 1698 / 2005 “Nonautomatic weighing instruments”. F1, E2 - Weights intended to be used with weighing instruments of accuracy of class I. F2 - Weights intended to be used for important commercial transactions (e.g. gold and precious stones) on weighing instruments of accuracy class II. M1 - Weights intended to be used with weighing instruments of accuracy class II. M2 - Weights intended to be used in normal commercial transactions and on weighing instruments of accuracy class III. M3 - Weights intended to be used on weighing instruments of accuracy classes III and IIII.

Best Sellers From Metrology Sector

GSO OIML R87:2021
OIML R87:2016 
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015 
Gulf Standard
Labeling requirements for prepackages
GSO OIML R 76-1:2009
OIML R 76-1:2006 
Gulf Standard
Non-automatic weighing instruments – Part 1: Metrological and technical requirements - Tests
GSO OIML R111-1:2007
OIML R111-1:2004 
Gulf Standard
Weights of classes E1, E2,F1,F2,M1,M1-2,M2,M2-3 and M3 Part 1: Metrological and Technical requirements

Recently Published from Metrology Sector

GSO ISO 80004-1:2024
ISO 80004-1:2023 
Gulf Standard
Nanotechnologies – Vocabulary — Part 1: Core vocabulary
GSO ISO 19749:2024
ISO 19749:2021 
Gulf Standard
Nanotechnologies — Measurements of particle size and shape distributions by scanning electron microscopy
GSO ISO 4373:2024
ISO 4373:2022 
Gulf Standard
Hydrometry — Water level measuring devices
GSO ISO 8529-3:2024
ISO 8529-3:2023 
Gulf Standard
Neutron reference radiation fields — Part 3: Calibration of area and personal dosemeters and determination of their response as a function of neutron energy and angle of incidence