GSO 2117:2011
Gulf Standard
·
Edition 1
Current Edition
·
Approved on
12 April 2011
Safety Requirements for Cord Extension Sets
GSO 2117:2011 Files
Arabic
140 Pages
Current Edition
Reference Language
355.0 SAR
English
102 Pages
Current Edition
330.0 SAR
GSO 2117:2011 Scope
This Saudi Standard applies to cord extension sets, rewirable and non rewirable, with earthing contact, with a rated voltage of 220 V having a rated current of 13 A or with a rated voltage of 127 V having a rated current of 15 A, intended for household and similar purposes, either indoors or outdoors.
NOTE 1 Cord extension sets with earthing can accept plugs of class II equipments.
This standard also applies to plugs incorporated in cord sets, to plugs and portable socket-outlets incorporated in cord extension sets and to plugs and socket-outlets which are a component of an appliance, unless otherwise stated in the standard for the relevant appliance.
This Standard also applies to cord extension sets which are intended to be used in a cable reel and therefore they become cable reels with a detachable flexible cable. For the combination of the cord extension set and the reel requirements and tests of IEC 61242 have to be fulfilled in addition.
This standard does not apply to
– cord extension sets with means for reeling;
– plugs, socket-outlets and couplers for industrial purposes;
– appliance couplers;
– plugs, fixed and portable socket-outlets for ELV;
NOTE 2 ELV values are specified in IEC 60364-4-41.
– fixed socket-outlets, automatic switches, etc.
NOTE 3 Socket-outlets with pilot lights are allowed provided that pilot lights comply with the relevant standard, if any.
Cord extension sets should be suitable for use at ambient temperatures not normally exceeding +45 °C, but their average over a period of 24h does not exceed +35 °C, with a lower limit of the ambient air temperature of -7 °C.
NOTE 4 Socket-outlets complying with this standard are only suitable for incorporation in equipment in such a way and in such a place that it is unlikely that the surrounding temperature exceeds 35 °C.
In locations where special conditions prevail, such as in ships, vehicles and the like and in hazardous locations, for example where explosions are liable to occur, special constructions may be required.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines
GSO 1899:2016
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems
Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS
GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC