GSO IEC 61058-2-4:2014

IEC 61058-2-4:1995
Gulf Standard   Current Edition · Approved on 25 December 2014

Switches for appliances - Part 2-4: Particular requirements for independently mounted switches

GSO IEC 61058-2-4:2014 Files

GSO IEC 61058-2-4:2014 Scope

This clause of part 1 is applicable except as follows: 1.1 Replacement: This International Standard applies to independently mounted switches for appliances (mechanical or electronic) actuated by hand, by foot or by other human activity, to operate or control electrical appliances and other equipment for household or similar purposes with a rated voltage not exceeding 480 V and a rated current not exceeding 63 A. These switches are intended to be operated by a person, via an actuating member or by actuating a sensing unit. The actuating member or sensing unit can be integral with or arranged separately, either physically or electrically, from the switch and may involve transmission of a signal, for example electrical, optical, acoustic or thermal, between the actuating member or sensing unit and the switch. Switches which incorporate additional control functions governed by the switch function are within the scope of this standard. This standard also covers the indirect actuation of the switch when the operation of the actuating member or sensing unit is provided by a remote control or a part of an appliance or equipment such as a door. NOTE 1 Electronic switches may be combined with mechanical switches giving full disconnection or microdisconnection. NOTE 2 Electronic switches without a mechanical switch in the supply circuit provide only electronic disconnection. Therefore, the circuit on the load side is always considered to be live. NOTE 3 For switches used in tropical climates, additional requirements may be necessary. NOTE 4 Attention is drawn to the fact that the standards for appliances may contain additional or alternative requirements for switches. NOTE 5 Throughout this standard, the word “appliance” means “appliance or equipment”. 1.2 This subclause of Part 1 is not applicable 1.3 This subclause of Part 1 is applicable. 1.4 This subclause of Part 1 is not applicable.

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines
GSO 1899:2016
 
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems

Recently Published from Electrical Sector

GSO IEC 61558-2-2:2024
IEC 61558-2-2:2022 
Gulf Standard
Safety of transformers, reactors, power supply units and combinations thereof - Part 2-2: Particular requirements and tests for control transformers and power supply units incorporating control transformers
GSO IEC 60664-1:2024
IEC 60664-1:2020 
Gulf Standard
Insulation coordination for equipment within low-voltage supply systems - Part 1: Principles, requirements and tests
GSO IEC 61936-2:2024
IEC 61936-2:2023 
Gulf Standard
Power installations exceeding 1 kV AC and 1,5 kV DC - Part 2: DC
GSO IEC TS 62915:2024
IEC TS 62915:2023 
Gulf Standard
Photovoltaic (PV) modules - Type approval, design and safety qualification - Retesting