GSO IEC 60099-5:2014
IEC 60099-5:2013
Gulf Standard
Historical
·
Approved on
25 December 2014
Surge arresters - Part 5: Selection and application recommendations
GSO IEC 60099-5:2014 Files
English
145 Pages
Historical
Reference Language
Obtaining this standard through the store is currently unavailable.
You can acquire it directly from its source or from one of the member countries stores
GSO IEC 60099-5:2014 Scope
This part of IEC 60099 is not a mandatory standard but provides information, guidance, and
recommendations for the selection and application of surge arresters to be used in threephase
systems with nominal voltages above 1 kV. It applies to gapless metal-oxide surge
arresters as defined in IEC 60099-4, to surge arresters containing both series and parallel
gapped structure – rated 52 kV and less as defined in IEC 60099-6 and metal-oxide surge
arresters with external series gap for overhead transmission and distribution lines (EGLA) as
defined in IEC 60099-8. In Annex H, some aspects regarding the old type of SiC gapped
arresters are discussed.
The principle of insulation coordination for an electricity system is given in IEC 60071 and
IEC 60071-2 standards. Basically the insulation coordination process is a risk management
aiming to ensure the safe, reliable and economic design and operation of high voltage
electricity networks and substations. The use of surge arrester helps to achieve a system and
equipment insulation level and still maintaining an acceptable risk and the best economic of
scale.
The introduction of analytical modelling and simulation of power system transients further
optimise the equipment insulation level. The selection of surge arresters has become more
and more important in the power system design and operation. It is worthwhile to note that the
reliability of the power system and equipment is dependent on the safety margin adopted by
the user in the design and selection of the equipments and surge arresters.
Surge arrester residual voltage is a major parameter of which most users have paid a lot of
attention to when selecting the type and rating. The typical maximum surge arresters residual
voltage are given in Annex F. It is likely, however, that for some systems, or in some
countries, the system reliability requirements and design are sufficiently uniform that the
recommendations of the present standard may lead to the definition of narrow ranges of
arresters. The user of surge arresters will, in that case, not be required to apply the whole
process introduced here to any new installation and the selection of characteristics resulting
from prior practice may be continued.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners

GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES

GSO 35:2007
Gulf Standard
Methods of test
for lead-acid starter batteries used for motor vehicles
and internal combustion engines

GSO 1899:2016
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems

Recently Published from Electrical Sector
GSO 2770:2024
Gulf Standard
WATER HEATERS - ENERGY PERFORMANCE REQUIREMENTS

GSO ISO 22975-4:2024
ISO 22975-4:2023
Gulf Standard
Solar energy
— Collector components and materials
— Part 4: Glazing material durability and performance


GSO IEC 60794-1-306:2024
IEC 60794-1-306:2023
Gulf Standard
Optical fibre cables - Part 1-306: Generic specification - Basic optical cable test procedures - Cable element test methods - Ribbon torsion, Method G6


GSO IEC 62149-3:2024
IEC 62149-3:2023
Gulf Standard
Fibre optic active components and devices - Performance standards - Part 3: Modulator-integrated laser diode transmitters for 40-Gbit/s fibre optic transmission systems

