GSO IEC 61557-15:2016

IEC 61557-15:2014
Gulf Standard   Current Edition · Approved on 22 December 2016

Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems

GSO IEC 61557-15:2016 Files

GSO IEC 61557-15:2016 Scope

IEC 61557-15:2014 specifies requirements related to functional safety and is based on the IEC 61508 standard series for the realization of Insulation Monitoring Devices (IMD) as specified in IEC 61557-8 and for Insulation Fault Location Systems (IFLS) according to IEC 61557-9, according to phase 10 of the IEC 61508-1 lifecycle. These devices provide safety related functions for IT systems. This part of IEC 61557 is - concerned only with functional safety requirements intended to reduce the functional risk during the use of IMDs and IFLSs; - restricted to risks arising directly from the device itself or from several IMDs or IFLSs working together in a system; and - intended to define the basic safety functions provided by the devices. This part of IEC 61557 does not - deal with electrical safety according to IEC 61010-1 and the requirements of IEC 61557-8 and IEC 61557-9; - cover the hazard and risk analysis of a particular use of the IMD or IFLS; - identify all the safety functions for the application in which the IMD or IFLS is used; and - cover the IMD or IFLS manufacturing process. Functional safety requirements depend on the application and should be considered as part of the overall risk assessment of the specific application. The supplier of IMDs and IFLSs is not responsible for the application. The application designer is responsible for the risk assessment and for specifying the overall functional safety requirements of the complete IT system and he should select the functional safety level (SIL) of the IMD and/or IFLS when their safety function is part of the functional safety assessment in the IT system. This publication is to be read in conjunction with IEC 61557-8:2007 and IEC 61557-9:2009

Best Sellers From Electrical Sector

GSO 2530:2016
 
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
GSO 34:2007
 
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR MOTOR VEHICLES AND INTERNAL COMBUSTION ENGINES
GSO 35:2007
 
Gulf Standard
Methods of test for lead-acid starter batteries used for motor vehicles and internal combustion engines
GSO 1899:2016
 
Gulf Standard
GCC Standard voltages and frequencies for AC transmission and distribution systems

Recently Published from Electrical Sector

GSO IEC 60512-99-003:2024
IEC 60512-99-003:2023 
Gulf Standard
Connectors for electrical and electronic equipment - Tests and measurements - Part 99-003: Endurance test schedules - Test 99c: Test schedule for balanced single-pair connectors separating (unmating) under electrical load
GSO IEC 60794-1-309:2024
IEC 60794-1-309:2023 
Gulf Standard
Optical fibre cables - Part 1-309: Generic specification - Basic optical cable test procedures - Cable element test methods - Bleeding and evaporation of filling or flooding compounds, Method G9
GSO IEC 63119-1:2024
IEC 63119-1:2019 
Gulf Standard
Information exchange for electric vehicle charging roaming service - Part 1: General
GSO IEC TR 63401-1:2024
IEC TR 63401-1:2022 
Gulf Standard
Dynamic characteristics of inverter-based resources in bulk power systems - Part 1: Interconnecting inverter-based resources to low short circuit ratio AC networks