GSO ISO 80601-2-13:2024

Gulf Standard   Current Edition
· Approved on 25 April 2024 ·

Medical electrical equipment — Part 2-13: Particular requirements for basic safety and essential performance of an anaesthetic workstation

Anaesthetic, respiratory and reanimation equipment
Including medical gas installations

GSO ISO 80601-2-13:2024 Files

English 103 Pages
Current Edition Reference Language

GSO ISO 80601-2-13:2024 Scope

This document is applicable to the basic safety and essential performance of an anaesthetic workstation for administering inhalational anaesthesia whilst continuously attended by a professional operator.

This document specifies particular requirements for a complete anaesthetic workstation and the following anaesthetic workstation components which, although considered as individual devices in their own right, may be utilized, in conjunction with other relevant anaesthetic workstation components, to form an anaesthetic workstation to a given specification:

  • anaesthetic gas delivery system;
  • anaesthetic breathing system;
  • anaesthetic gas scavenging system (AGSS);
  • anaesthetic vapour delivery system;
  • anaesthetic ventilator;
  • monitoring equipment;
  • alarm system;
  • protection device.

NOTE 1        Monitoring equipment, alarm systems and protection devices are summarized in Table AA.1.

An anaesthetic workstation supplied complete and its individual components are considered as ME equipment or ME systems with regard to the general standard.

NOTE 2        The applicability of this document is indicated in Table AA.2.

This document is also applicable to those accessories intended by their manufacturer to be connected to an anaesthetic workstation where the characteristics of those accessories can affect the basic safety and essential performance of the anaesthetic workstation.

If a clause or subclause is specifically intended to be applicable to anaesthetic workstation components or its accessories only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to an anaesthetic workstation and its individual components including accessories, as relevant.

Hazards inherent in the intended physiological function of an anaesthetic workstation and its individual components including accessories within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+AMD1:2012+AMD2:2020, 7.2.13 and 8.4.1.

NOTE 3        See also IEC 60601-1:2005+AMD1:2012+AMD2:2020, 4.2.

This document is not applicable to any anaesthetic workstation intended for use with flammable anaesthetic agents, as determined by Annex BB.

Best Sellers From Health Sector

GSO 2017:2023
 
Gulf Standard
Personal Care and Baby Wet Wipes
GSO 2241:2023
 
Gulf Standard
Cosmetic Products - Body Cleaners
GSO 1223:2023
 
Gulf Standard
Cosmetic Products-Deodorants
GSO 2063:2023
 
Gulf Standard
Cosmetic Products - Hair Conditioner (Balsam)

Recently Published from Health Sector

GSO ISO 11608-6:2024
ISO 11608-6:2022 
Gulf Standard
Needle-based injection systems for medical use — Requirements and test methods — Part 6: On-body delivery systems
GSO ISO 16256:2024
ISO 16256:2021 
Gulf Standard
Clinical laboratory testing and in vitro diagnostic test systems — Broth micro-dilution reference method for testing the in vitro activity of antimicrobial agents against yeast fungi involved in infectious diseases
GSO ISO 14708-3:2024
ISO 14708-3:2017 
Gulf Standard
Implants for surgery — Active implantable medical devices — Part 3: Implantable neurostimulators
GSO ISO 17069:2024
ISO 17069:2020 
Gulf Standard
Accessible design — Consideration and assistive products for accessible meeting